Journals - MOST Wiedzy

Logo

Selected problems concerning strength of a floating dock with roof

Abstract

The paper presents models and results of the structural strength analysis of a roofed floating dock. Computed thickness of the roof structure walls capable of withstanding the environmental loads is 24 mm. Heavy sliding roof segments generate the dock pontoon floor plate stresses reaching 25% of the permissible stress value. The dock pontoon structure effort under the roof and docked ship weight load was minimized by seeking an optimum balancing ballast distribution. The problem was solved in two ways: analytically, by means of a simplified model of a continuous beam on elastic foundation and numerically, using the linear programming method to construct an accurate discrete FEM model.

Keywords:

floating dock structure and strength, FEM computations, linear programming

Details

Issue
Vol. 12 No. S1 (2005)
Section
Latest Articles
Published
30-09-2021
Licencja:
Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

Open Access License

This journal provides immediate open access to its content under the Creative Commons BY 4.0 license. Authors who publish with this journal retain all copyrights and agree to the terms of the CC BY 4.0 license.

 

Authors

  • Marian Bogdaniuk

    Gdańsk University of Technology
  • Zenon Górecki

    Gdańsk University of Technology
  • Wojciech Puch

    Gdańsk University of Technology

Download paper